Milesight EM500-UDL-C050 Ultrasonic Distance/Level Sensor
The EM500-UDL is designed for objects distance or level detection in harsh environments and transmitting data using LoRaWAN® technology. With this low power consumption technology, EM500-UDL can work up to 10 years with 19000 mAh battery. Combining with Milesight LoRaWAN® gateway and Milesight IoT Cloud solution, users can manage all sensor data remotely andvisually. EM500-UDL is widely used for outdoor applications like flood monitoring, granary level monitoring, etc.
Features:
- Accurate Non-Contact Detection with Ultrasonic Waves
- Wide Measuring Range and Multiple Probing Options
- Exceptional IP67 Rated Performance and UV Resistant
- 10 Years Long Battery Life
- LoRaWAN® Wireless Deployment
- Remote Management via Milesight IoT Cloud
- Easy NFC Configuration
Wireless Transmission | |
---|---|
Technology | LoRaWAN® |
Frequency | CN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4 |
Tx Power | 16dBm (868) / 20dBm (915) / 19dBm (470) |
Sensitivity | -137dBm @300bps |
Mode | OTAA/ABP Class A |
Measurement | |
Range & Accuracy |
W050: 0.3 - 5 m, ±1% FS W100: 0.5 - 10 m, ±1% FS C050: 0.25 - 5 m, ± (1+0.3%*S) cm, S=distance C100: 0.25 - 8 m, ± (1+0.3%*S) cm, S=distance |
Resolution | 1 mm |
Operation | |
Power On & Off | NFC, Power Button (Internal) |
Configuration | Mobile App (via NFC) or PC software (via USB Type-C) |
Physical Characteristics | |
Power Supply | 19000 mAh Li-SOCL2 battery (ER34615) |
Battery Life* | 10 years (10 min interval) |
Operating Temperature |
W050/W100: -30°C to +65°C C050/C100: -15°C to +60°C |
Relative Humidity | 0% to 80% (non-condensing) |
Ingress Protection | IP67 |
Dimension | 156.1 × 71 × 69.5 mm (6.1 × 2.8 × 2.7 in) |
Installation | Pole, wall or DIN Rail Mounting |
Approvals | |
Regulatory | CE, FCC, RoHS, LoRaWAN® Certified |
EMC | EN 55032, EN 55035 |
EMS | IEC 61000-4-2 Level 3, IEC 61000-4-3 Level 2, IEC 61000-4-8 Level 4 |
Radio Frequency | FCC Part 15B, FCC Part 15.247, EN 300 330, EN 301 489-1/3, EN 300 220-1/2 |
Safety | EN62368-1 |